2.6 Help
Q
How do I change the extension numbering plan from 3-digit numbers to 4-digit
numbers?
A
Perform the following steps:
1.
2.
Q
How do I set a 3-digit numbering plan?
A
There are 2 methods of creating a 3-digit numbering plan, using 2.8.8 [2-6-1]
Numbering Plan—Main:
1.
2.
For more details, see What is the procedure to modify the Numbering Plan?.
Q
What is the procedure to modify the Numbering Plan?
A
Perform the following steps:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
Q
When modifying the Numbering Plan, I cannot change the Leading Number.
54
PC Programming Manual
Open the 2.8.8 [2-6-1] Numbering Plan—Main screen.
Enter a 2-digit number in Leading Number, or change No. of Additional Digits
from "x" to "xx".
For more details, see What is the procedure to modify the Numbering Plan?.
Set the leading number to be 2 digits, with one additional digit. This method allows
a maximum of 10 extensions.
Example: Leading Number = 10; No. of Additional Digits = x
In this example, extension numbers 100 to 109 can be used.
Set the leading number to be one digit, with 2 additional digits. This method allows
a maximum of 100 extensions.
Example: Leading Number = 1; No. of Additional Digits = xx
In this example, extension numbers 100 to 199 can be used.
Confirm that the Numbering Plan you will change is not currently being used by any
extensions (see 2.4.4 Tool—Extension List View).
If it is being used by extensions, temporarily change the extension numbers of those
extensions to that of another numbering plan, or delete the extension number (see
2.10.1 [4-1-1] Wired Extension—Extension Settings and 2.10.8 [4-2-1] Portable
Station—Extension Settings).
Clear the Leading Number cell.
Click Apply.
Modify the No. of Additional Digits cell as required.
Click Apply.
Enter the desired value in the Leading Number cell.
Click Apply.
Set all extension ports to OUS status.
On the relevant screens, set the extension numbers of extensions to the desired
values.
Set all extension ports back to INS status.