Draining And Drying Procedure - Sanyo VW-VF10BG Technical Data & Service Manual

Floor-mounted model with virus washer function
Hide thumbs Also See for VW-VF10BG:
Table of Contents

Advertisement

5. Draining and Drying Procedure

Perform draining and drying if the system is relocated or stored without being operated
for a long period of time.
1.
Set the fan speed to be used for drying.
After setting the fan speed to "High," press the ON/OFF button to stop operation.
2.
Remove the water tank and empty the water from of it.
3.
Press and hold the DRAIN/DRY button for 3 seconds.
The DRAIN/DRY lamp lights, and the water in the system flows
into the drainage tank.
4.
After waiting approximately 2 minutes, press the DRAIN/DRY button again.
This begins drying of the Virus Washer element.
5.
The fan starts operating. (The fan speed is "High.")
The "TREATED AIR VOLUME" sign begins blinking.
6.
If the system is to be relocated, leave it operating for approximately 20 minutes.
If the system is to be stored, leave it operating for approximately 2 hours.
(This is necessary make the Virus Washer element fully dry.)
7.
Press the DRAIN/DRY button again.
The fan stops and the "TREATED AIR VOLUME" sign turns OFF.
8.
Remove the front lower panel and empty the drainage tank. (Refer to "Draining Procedure.")
9.
Return the drainage tank and water tank to their original positions.
Verify that the DRAIN lamp has turned OFF.
If the DRAIN lamp is not OFF, again insert the tank all the way to the inside.
10.
Re-install the front lower panel, and relocate or store the system.
CAUTION
G
It is not possible to drain the system water when the water tank is installed.
Be sure to remove the water tank.

Draining and drying procedure

2 - 8
Using this System
DRAIN/DRY button
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents