Clearing The Total Times (Filter, Water Change, Electrolyzing Unit Change) - Sanyo VW-VF10BG Technical Data & Service Manual

Floor-mounted model with virus washer function
Hide thumbs Also See for VW-VF10BG:
Table of Contents

Advertisement

2. Clearing the Total Times
(Filter, Water Change, Electrolyzing Unit Change)
Follow the procedure below to clear (reset) the total times for filter cleaning, water change, and electrolyzing unit
change after servicing and maintenance are completed.
1. Clearing the total times for filter and water change
Step 1
Short-circuit maintenance pin 1 on the control PCB.
Step 2
Press the FILTER RESET button. The buzzer sounds once and the total times are cleared.
2. Clearing the total time for electrolyzing unit change
Step 1
Short-circuit maintenance pin 2 on the control PCB.
Step 2
Press the FILTER RESET button. The buzzer sounds once and the total times are cleared.
5
Maintenance pin 1
Maintenance pin 2
5 - 5
PCB and Functions