Preventive Maintenance Check List - Panasonic UF-9000 Service Handbook

Facsimile
Hide thumbs Also See for UF-9000:
Table of Contents

Advertisement

2.4.

Preventive Maintenance Check List

The chart outlined below is a general guideline for maintenance. The list is for an average usage of 50
transmitted and received documents per day. Needless to say, the environmental conditions and actual use
will vary these factors. The chart below is for reference only.
Preventive
Maintenance
No.
Parts
ADF Unit
1 Separation Rubber
2 Pickup Roller
3 ADF Roller
4 Feed Roller
Paper Feed Module
5 Pickup Roller
6 Separator Pad
Bias Transfer Roller
7
(BTR)
2nd Paper Feed Module
8 Pickup Roller
9 Separator Pad
Fuser Unit
10 Fuser Unit
Note:
1. Wet Cloth represents a soft cloth saturated with water. For stubborn toner accumulation, wipe with a
soft cloth saturated with Isopropyl Alcohol first, then follow up with a soft cloth saturated with water.
2. The Maintenance Cycle is based on the Counter Information for each individual module.
To verify the counter information, print the Total Counter List using the Service Mode: F7 - Electronic
Counter - 00 (List Print).
3. Cleaning, Replacement and Adjustment Cycle (Sheet) are based on using Panasonic's recommended
standard paper and supplies. These cycles may vary with the kind of paper used, Paper size,
orientation, print duty, continuous/interval print and/or ambient conditions.
• Total Counter View Mode on the LCD
The Total Counter can be displayed on the Panel Display by pressing "COPY SIZE" and "PAPER TRAY"
keys simultaneously in Standby mode for quick reference.
TOTAL COUNTER
• LCD Contrast Adjustment
Press holding the "CLEAR" key and press "ORIGINAL SIZE" key for Lighter or "COPY SIZE" key for
Darker.
Ver. 2.0
Cleaning
Ref.
Cycle
No.
(Sheet)
547
10K
Wet soft cloth
414
10K
Wet soft cloth
417
10K
Wet soft cloth
516
10K
Wet soft cloth
1316
10K
Wet soft cloth
1615
10K
Wet soft cloth
1503
10K
Dry soft cloth
1733
10K
Wet soft cloth
1812
10K
Wet soft cloth
1117
-
1234
Replacement/Adjustment
Cycle
Method
(Sheet)
50K
100K
100K
100K
85K
85K
85K
85K
85K
-
85K
32
UF-9000
DP-180/190
Ref.
Counter
Procedure
Refer to
2.2.1. of the
F7-08
Service
Manual
Refer to
2.2.9. of the
Service
Manual
F7-12
Refer to
2.2.10. of the
Service
Manual
Refer to
2.2.12. of the
F7-13
Service
Manual
Refer to
2.2.8. of the
F7-02
Service
Manual
JUN 2004