11.5 OUT2 (Heating/Cooling control) action [Reverse (Heating) action]

ON
Control
action
OFF
Relay contact
output (OUT1)
Cycle action is performed according to deviation.
+
Non-contact
voltage output
-
(OUT1)
Cycle action is performed according to deviation.
+
DC current
output (OUT1)
-
Changes continuously according to deviation.
Relay contact
output (OUT2)
Non-contact
voltage output
(OUT2)
Indicator
(OUT1)
Lit
Indicator
(OUT2)
Unlit

11.6 OUT2 (Heating/Cooling control) action [Reverse (Heating) action] (When setting dead band)

ON
Control action
OFF
Relay contact
output (OUT1)
Cycle action is performed according to deviation.
+
Non-contact
voltage output
-
(OUT1)
Cycle action is performed according to deviation.
+
DC current
20mA DC
output (OUT1)
-
Changes continuously according to deviation.
Relay contact
output (OUT2)
Non-contact
voltage output
(OUT2)
Indicator
(OUT1)
Lit
Indicator
(OUT2)
Unlit
Heating P-band
Heating
action
SV setting
7
7
8
8
7
7
+
12V DC
12/0V DC
8
8
-
7
7
+
20mA DC
20 to
4mA DC
8
8
-
5
6
Cycle action is performed according to deviation.
5
+
0V DC
6
-
Cycle action is performed according to deviation.
Heating P-band
Dead band
Heatng
action
SV setting
7
7
8
8
7
7
+
+
12V DC
12/0V DC
8
8
-
-
7
7
+
+
20 to 4mA DC
8
8
-
-
(Cooling P-band)
ON
(Cooling
action)
OFF
7
8
7
+
0V DC
8
-
7
+
4mA DC
8
-
5
5
6
6
5
5
+
+
12/0V DC
12V DC
6
6
-
-
Unlit
Lit
(Cooling P-band)
7
8
7
0V DC
8
7
4mA DC
8
5
5
6
6
Cycle action is performed according to deviation.
5
5
+
+
0V DC
12/0V DC
6
6
-
-
Cycle action is performed according to deviation.
31
Heating/Cooling control can be used
by adding Heating/Cooling control
option.
Heating proportional band can be
set during [6] OUT1 proportional band
setting, and cooling proportional band
can be set during [7] OUT2 proportional
band setting in the Sub setting mode.
(p.14)
[48] Direct/Reverse control can be
set in the Setup mode. (p.21)
: Acts ON (lit) or OFF (unlit).
: Represents Heating control
action.
: Represents Cooling control
action.
ON
Heating/Cooling control can
(Cooling
be used by adding Heating/
action)
Cooling control option.
OFF
Heating proportional band can
be set during [6] OUT1
proportional band setting, and
cooling proportional band
can be set during [7] OUT2
proportional band setting in the
Sub setting mode. (p.14)
Dead band can be set during
[36] Overlap band/Dead band
setting in the Setup mode.(p.19)
5
[48] Direct/Reverse control can
be set in the Setup mode. (p.21)
6
5
+
12V DC
6
-
Unlit
Lit
: Acts ON (lit) or OFF
(unlit).
: Represents Heating
control action.
: Represents Cooling
control action.