Front Traction Manifold Service (Fig. 73)
For front traction manifold cartridge valve service proce-
dures, see Control Manifold Cartridge Valve Service in
this section. Refer to Figure 73 for front traction manifold
cartridge valve and plug installation torque.
IMPORTANT: A flow control orifice is located be-
neath the plug in the front traction manifold port OR.
If the orifice is removed from the manifold port,
make sure to label its position for assembly pur-
poses. When installing the orifice in the manifold,
make sure that the orifice is properly tightened in
the port.
Groundsmaster 4000--D/4010--D
Page 4 - - 105