66-11
Purpose
Operation test, check
Function (Content)
Used to check the output operation of FAX G3
mode 300BPS.
(Used to check the MODEM operation.)
Send level Max.
(Only when FAX is installed.)
Section
FAX
Item
Operation
Operation/Procedure A signal of 300bps is outputted. (Level Max.)
Enter a number during execution to change the
kind of signal.
Press START to start sending a voice message.
Press CUSTOM SETTINGS to terminate.
SIMULATION 66-11
300bps SIGNAL OUTPUT.(LEVEL MAX) SELECT 1-6, AND PRESS
START.
1.NO SIGNAL 2.11111
3.11110
5.010101
6.00001
Press [START] key.
SIMULATION 66-11
300bps SIGNAL OUTPUT.(LEVEL MAX) SELECT 1-6, AND PRESS
START.
EXECUTING...
1.NO SIGNAL 2.11111
3.11110
5.010101
6.00001
Select 3 and press [START] key.
Same
display
SIMULATION 66-11
300bps SIGNAL OUTPUT.(LEVEL MAX) SELECT 1-6, AND PRESS
START.
EXECUTING...
1.NO SIGNAL 2.11111
3.11110
5.010101
6.00001
<List of set values>
1
NO SIGNAL
2
11111
3
11110
4
00000
5
010101
6
00001
1
4.00000
Press [CUSTOM SETTINGS] key.
1
4.00000
3
4.00000
Press [CUSTOM SETTINGS] key.
No signal
AR-FX12 SIMULATIONS, FAX SOFTWARE SWITCH 6-17
66-12
Purpose
Setup
Function (Content)
Used to check the output operation of FAX G3
mode 300BPS.
(Used to check the MODEM operation.)
Signals are sent in the send level set with the
soft switch. (Only when FAX is installed.)
Section
FAX
Item
Operation
Operation/Procedure A signal of 300bps is outputted.
(Send level is set with soft SW.)
Enter a number during execution to change the
kind of signal.
Press CUSTOM SETTINGS to terminate.
SIMULATION 66-12
300bps SIGNAL OUTPUT.(SOFT SW.) SELECT 1-6, AND PRESS
START.
1.NO SIGNAL 2.11111
3.11110
5.010101
6.00001
Press [START] key.
SIMULATION 66-12
300bps SIGNAL OUTPUT.(SOFT SW.) SELECT 1-6, AND PRESS
START.
EXECUTING...
1.NO SIGNAL 2.11111
3.11110
5.010101
6.00001
Select 2 and press [START] key.
Same
display
SIMULATION 66-12
300bps SIGNAL OUTPUT.(SOFT SW.) SELECT 1-6, AND PRESS
START.
EXECUTING...
1.NO SIGNAL 2.11111
3.11110
5.010101
6.00001
<List of set values>
1
NO SIGNAL
2
11111
3
11110
4
00000
5
010101
6
00001
1
4.00000
Press [CUSTOM SETTINGS] key.
1
4.00000
2
4.00000
Press [CUSTOM SETTINGS] key.
No signal