Step
1
Installing the Anti-siphon
Fill Receptacle
Parts needed for this step:
1
90 degree tting
1
Quick coupler
1
Hose adapter
1
Fill receptacle bracket
1
Flange-head bolt, 5/16 x 3/4 inch
1
Anti-siphon hose
Procedure
1. Place the fill receptacle bracket over the
threaded hole in the tank and secure it with a
flange-head bolt (5/16 x 3/4 inch) (Figure 3).
Figure 3
1. Fill receptacle bracket
2. Threaded hole in the tank
3. Flange bolt, 5/16 x 3/4 inch 7. Anti-siphon hose
4. 90 degree elbow tting
2. Place the threaded end of the 90 degree elbow
fitting through the bracket and thread the
quick coupler onto it, securing it to the bracket
(Figure 3).
Note: Install the fitting with the open end
pointing toward the large opening in the
bracket and toward the tank opening so the
water will arc into the tank when you fill it.
5. Quick coupler
6. Hose adapter
3. Install the hose adapter into the quick coupler
(Figure 3).
4. Lock the adapter into place by swinging the
levers toward the adapter and then secure them
with the hairpin cotters (Figure 3).
5. Install the anti-siphon hose through the large
opening on the bracket and onto the barbed
end of the 90 degree elbow fitting (Figure 3).
Important: Do not lengthen the hose to
allow contact with the tank fluids.
Step
2
Installing the Spray Pro
Monitor
Parts needed for this step:
1
Spray Pro Monitor
1
Spray Pro Decal
1
Bracket
2
Flange-head bolt, 3/4 inch
2
Flange nut, 1/4 inch
2
Knob
2
Washer
2
Carriage bolt
Procedure
1. Install the Spray Pro Decal to the monitor
(Figure 4).
Figure 4
1. Spray pro monitor
2. Decal, Upper half
Note: Be sure to orient the decal as shown
in Figure 20.
14
3. Decal, Lower half