Toro 41177 Multi-Pro 1250 Operator's Manual page 22

Turf sprayer
Hide thumbs Also See for 41177 Multi-Pro 1250:
Table of Contents

Advertisement

Agitation Control Valve
This valve is located on the right side of the tank
(Figure 19). Turn the knob on the valve to the
9 o'clock position to turn on the tank agitation
and to the 3 o'clock position to turn off the tank
agitation.
Figure 19
1. Agitation control valve
Note: For agitation to work, the pump must
be on and the engine must be running above an
idle. If you stop the sprayer and need agitation on,
place the range selector in the Neutral position, set
the parking brake, press the accelerator pedal to
the floor, turn the pump On and turn the neutral
engine speed lock On.
2. Pressure gauge
Pressure Gauge
The pressure gauge is located to the right of the
tank (Figure 19). This gauge shows the pressure
of the fluid in the system in psi and kPa. Use the
gauge to adjust the by-pass valves whenever you
change nozzles.
Anti-siphon Fill Receptacle
To the front of the tank cover is a hose receptacle
with a threaded fitting, a 90 degree barbed fitting,
and a short hose which you can direct toward
the tank opening. This receptacle allows you to
connect a water hose to it and fill the tank with
water without contaminating the hose with the
chemicals in the tank.
Important: Do not lengthen the hose to
allow contact with the tank fluids.