Problem
The Area is inaccurate.
The Distance is inaccurate.
The monitor does not
display Application Rate or
Total Volume.
The Total Volume is
inaccurate.
The monitor displays 6553.5
when in the Application Rate
setting.
The monitor is erratic in
operation.
The displayed
measurements do not
make sense.
The monitor reads "OFL."
Possible Cause
1. The sprayer width is not
correctly entered.
2. The speed sensor is not
calibrated correctly.
3. The speed sensor is
damaged.
1. The speed sensor is not
calibrated correctly.
2. The speed sensor is
damaged.
1. The monitor cable is
loose.
2. The ow meter is dirty or
clogged.
3. The ow meter is not
calibrated correctly.
4. The ow meter is
damaged.
1. The ow meter is dirty or
clogged.
2. The ow meter is not
calibrated correctly.
3. The ow meter is
damaged.
1. The monitor is not
receiving data from the
speed sensor.
1. A two-way radio is too
close to the monitor or
its cables.
1. The Units of
Measurement is set
to a system other than
what you expect.
1. The data has exceeded
the maximum allowed.
68
Corrective Action
1. Check and set the
appropriate Width in
the calibration mode.
2. Calibrate the speed
sensor.
3. Contact your Authorized
Service Dealer.
1. Calibrate the speed
sensor.
2. Contact your Authorized
Service Dealer.
1. Connect the monitor
cable.
2. Clean the ow meter.
3. Calibrate the ow meter.
4. Contact your Authorized
Service Dealer.
1. Clean the ow meter.
2. Calibrate the ow meter.
3. Contact your Authorized
Service Dealer.
1. Contact your Authorized
Service Dealer.
1. Keep two-way radios
away from the monitor
and its cables.
1. Check the Units of
Measurement to ensure
that it is set correctly.
1. Press and hold the
[Reset] button to clear
the monitor.