Save settings in sfsv35dm.ini [Y/N]:
Note: The editor name refers to the 'edit' function in DOS 5.0 and upwards. This editor must be
present and the path from the root to DOS must have been set in the autoexec.bat file. If
you want to use another editor, always use an ASCII editor. Wordperfect is not an ASCII
editor and cannot be used.
If you press only <CR> for the COM port settings, the value following the colon is chosen.
To enter the baudrate, two digits will be sufficient.
For the file names as well as for the editor name, you can also specify the path. This is required
if the files are not in the same directory as the tool and if there is no path set DOS.
Choice 5 (Exit)
The 'exit' function causes the tool to go back to DOS.
4.4.3.

Data File Format

The data that is to be stored into the console must be conform a defined format. Otherwise
the store operation fails. In the following subsections the data formats for the files are
explained.
The Directory File
The directory file format must be as follows:
<name>;<DNR>[;[<department/branch>] [;<second DNR>]]<CR>
The length of the fields is defined as follows:
- Name
- DNR
- Department (optional)
- Second DNR (optional)
The following gives an example of a directory file:
ADAMS G.;345612;FACTORY;341278
HARRIS A.;567821;;765489
JONES S.;543673
:
21 characters.
:
20 digits.
:
15 characters.
:
20 digits.
41