X55.1 Customer Interface - Siemens SINAMICS S120 Manual

Modular motion control drive
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Cabinet Modules
5.5 Booksize format Motor Modules
Mounting grid arrangement in the cabinet
The area for connecting the Motor Modules in the cabinet is divided into three grid widths:
● 100 mm
● 200 mm
● 300 mm
The table below shows the grid width assigned to the various Motor Modules.
Table 5- 23
Grid width
100 mm
200 mm
300 mm
Note
The space available for the Motor Modules in the Booksize Base Cabinets is determined by
taking the actual space and subtracting a clearance of 200 mm.
5.5.3

X55.1 Customer interface

Description
The customer terminal block (-X55.1) is mounted as standard in the cabinet for each
Booksize Cabinet Kit. It provides the function-related inputs/outputs for temperature
monitoring and for the "Safe Torque Off" and "Safe Stop 1" functions.
Note
All other cabinet interfaces and connections are explained in the circuit and terminal
diagrams on the customer DVD supplied.
178
The assignment of the Motor Modules according to grid width
Assignment of Motor Modules (see the section titled "Technical data")
3 to 30 A Single Motor Modules
45 to 85 A Single Motor Modules, 3 to 18 A Double Motor Modules
132 ... 200 A Single Motor Module
Cabinet Modules
Manual, (GH5), 05/2010, A5E03263538A