Item
Activity
19
The date of manufacture can be determined from the rating plates of the power
components in the "Basic Line Module", "Smart Line Module", "Active Line Module",
"Motor Module in chassis format", and "Booksize Cabinet Kit" Cabinet Modules. If the
period from the date of manufacture to initial commissioning or the downtime of the
power components is shorter than 2 years, the DC link capacitors do not have to be
reformed. If the unit has not been operational for longer than 2 years, then the DC link
capacitors must be reformed as described in this Manual in the Chapter titled
"Maintenance and servicing", section "Reforming the DC link capacitors".
Signal connections
20
Cabinet operation by higher-level controller/control room.
The control cables must be connected in accordance with the interface assignment
and the shield applied.
To prevent interference, the control cables must be laid separately from the power
cables.
Cabling and connections must always comply with the relevant EMC guidelines.
(→ See the chapter titled "Electrical installation")
21
DRIVE-CLiQ cables
Options
22
G30,
CBC10 Communication
Board
23
G33,
CBE20 Communication
Board
24
K01 - K05,
Safety license for
1 - 5 axes
25
K46,
SMC10 Sensor Module
Cabinet Modules
Manual, (GH5), 05/2010, A5E03263538A
All DRIVE-CLiQ cables must be connected correctly.
The permissible cable lengths should be carefully
observed.
(→ See "S120 Commissioning Manual, Rules for wiring
with DRIVE-CLiQ")
(→ See "S120 Equipment Manual for Booksize Power
Units, DRIVE-CLiQ Cabinet Gland" and "S120 Equipment
Manual for Booksize Power Units, DRIVE-CLiQ Coupling")
The supplied CBC10 may only be inserted when the
Control Unit is disconnected from the power supply.
(→ See the chapter titled "Options", section "G30, CBC10
Communication Board")
The supplied CBE20 may only be inserted when the
Control Unit is disconnected from the power supply.
Note the MAC address before inserting!
(→ See the chapter titled "Options", section "G33, CBE20
Communication Board")
Activating the safety licenses.
(→ See Chapter "Options" in Section "K01 - K05, Safety
license for 1 - 5 axes")
The SMC10 Sensor Module is used for detecting the
actual motor speed and the rotor position angle.
The following encoders are supported by the SMC10
Sensor Module:
Resolver, 2 pole
Resolver, multi-pole
(→ See the chapter titled "Options", section "K46, SMC10
Sensor Module for detecting the actual motor speed and
the rotor position angle")
Electrical installation
4.2 Electrical installation: Checklist
Applicable?/Completed?