Siemens SINAMICS S120 Manual page 184

Modular motion control drive
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Cabinet Modules
5.5 Booksize format Motor Modules
Table 5- 28
Technical data for Motor Modules in Booksize Cabinet Kit format, Double Motor Modules, line voltage
3 AC 380 ... 480 V, DC link voltage 510 ... 720 V DC
Order no.
Unit rating
- at I
(50 Hz 400 V)
1)
N DC
- at I
(50 Hz 400 V)
1)
H DC
- at I
(60 Hz 460 V)
2)
N DC
- at I
(60 Hz 460 V)
2)
H DC
Output current
- Rated current I
N A
- Base load current I
H 3)
- Maximum current I
max A
DC link current I
d 4)
Power demand
- 24 V DC, max.
DC link capacitance
Pulse frequency
5)
- Rated frequency
- Pulse frequency, max. with current derating
Power loss, max.
6)
- at 50 Hz 400 V
- at 60 Hz 460 V
Cooling air requirement
Sound pressure level L
pA
Motor connection U2, V2, W2
- Connection cross section, max. (IEC)
Cable length, max.
7)
- shielded
- unshielded
PE/GND connection
- Busbar cross section
- Connection cross section, max. (IEC)
Degree of protection
Weight, approx.
Installation width
Rated output of a typ. 6-pole standard induction motor based on I
1)
Rated output of a typ. 6-pole standard induction motor based on I
2)
The base load current I
3)
For a DC link voltage of 600 V DC.
4)
For the interdependency of pulse frequency and max. output current/output frequency, see SINAMICS - Low-Voltage
5)
Configuration Manual on the customer DVD supplied with the device.
The specified power loss equals the maximum value at 100 % capacity utilization. The value in normal operation is
6)
lower.
Total of all motor cables. Longer cable lengths for specific configurations are available on request, see SINAMICS -
7)
Low-Voltage Configuration Manual on the customer DVD supplied with the device.
184
6SL3720-
kW
kW
hp
hp
A
A
A
A
A
µF
kHz
kHz
kW
kW
m
(1 m) at 50/60 Hz
dB(A)
mm
m
m
mm
mm
kg
mm
is based on a duty cycle of 150% for 60 s or 160% for 10 s with a duty cycle duration of 300 s.
H
2TE13-
0AB3
2 x 1.6
2 x 1.4
2 x 1.5
2 x 1
2 x 3
2 x 2.6
2 x 6
7.2
0.85
110
4
16
0.07
0.07
/s
0.008
3
<60
2
50
75
2
2
IP20
23.3
200
or I
at 3 AC 50 Hz 400 V.
N
H
or I
at 3 AC 60 Hz 460 V.
N
H
2TE15-
2TE21-
0AB3
0AB3
2 x 2.7
2 x 4.8
2 x 2.3
2 x 4.1
2 x 3
2 x 5
2 x 2
2 x 5
2 x 5
2 x 9
2 x 4.3
2 x 7.7
2 x 10
2 x 18
12
22
0.85
0.85
220
220
4
4
16
16
0.11
0.16
0.11
0.16
0.008
0.008
<60
<60
Terminal
6
50
50
75
75
PE busbar
600
240
IP20
IP20
23.3
23.3
200
200
Manual, (GH5), 05/2010, A5E03263538A
2TE21-
8AB3
2 x 9.7
2 x 8.2
2 x 10
2 x 10
2 x 18
2 x 15.3
2 x 36
43
0.85
710
4
16
0.32
0.32
0.016
<60
70
100
IP20
24.8
200
Cabinet Modules

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents