[783] E1 Group-B

Description
Assigns a signal code for Group-B parameters on the E1 line assigned to MFC-R2.
This programme is available for the KX-TD1232 only.
Selection
• Parameter number: 01 (Idle(1)) / 02 (Idle(2)) / 03 (Idle(3)) / 04 (No Billing) / 05 (Busy) /
06 (Unallocated) / 07 (Congestion) / 08 (Out of Service) / 09 (Collect Call Reject)
• Signal code: 00 through 15 (00=Undefined)
Default
Parameter 01 – 01; Parameter 05 – 02; Parameter 06 – 03; Parameter 07 and 08 – 04; Other
parameters – 00
Programming
1.
Enter 783.
Display: 783 GROUP-B
2.
Press NEXT.
Display: Parameter NO?
3.
Enter a parameter number.
To enter a parameter number 01, you can also press NEXT.
Display example: 01:01
4.
Enter the signal code.
To change the current entry, press CLEAR and enter the new code.
5.
Press STORE.
6.
To programme another parameter, press NEXT or PREV, or SELECT and the desired
parameter number.
7.
Repeat steps 4 through 6.
8.
Press END.
Conditions
Adjust to a setting of the connected telephone company.
Features Guide References
E1 Line Service
E1 Programming
4.4 E1 Line Programming
399