Locking out and releasing boards and ports
You can lock out and release ports using the lockout switch located on the board. The lockout
prevents renewed seizure after the current connection has finished. It creates
a port lockout in an outgoing direction on analog trunk boards.
a port lockout in outgoing and incoming directions on trunk boards.
a lockout of the entire board for subscriber line modules.
12.4.3

Manual Error Correction With HiPath 3000 Manager E

Initiating Restart (Reset)
This initiates an immediate hard restart of the entire system with the current CDB.
Initiating Reload Card
This the single board (loading Loadware) to reload.
Locking out and releasing boards and ports
HiPath 3000 Manager E enables you to lock out an entire subscriber line module or line circuit
module and individual ports. The lockout prevents renewed seizure after the current connection
has finished. Release or lockout settings are also retained after a reset.
However, you cannot lock out the first SLMO/SLU board because administration through Assis-
tant T runs on its first two ports.
When attempting to lock out the last active trunk, you are subsequently notified that remote ser-
vice through the service center is no longer possible.
You cannot use HiPath 3000 Manager E to release boards and ports locked out with the lockout
switch.
ALUM
You cannot initiate a power failure transfer to analog telephones using HiPath 3000 Manager E.