Toshiba strata DK8 Installation Instructions Manual page 169

Hide thumbs Also See for strata DK8:
Table of Contents

Advertisement

-.
NOTE:
The PDIU-DI
always
operates
as a DCE de-
vice; therefore,
unlike the PDIU-DS,
it has no
in ternal jumpers.
3) Connect
the appropriate
RS-232
cable
be-
tween the PDIU-Dl's
DB-25 female connector
and the PC's appropriate
asynchronous
serial
communications
port connector
(COM port).
IMPORTANT
NOTE!
Check
the PC manufacturer's
serial
com-
munication
port
interface
documentation
for correct
RS-232
pin
requirements;
re-
quirements
vary with each manufacturer.
The number
of EIA RS-232 signals
required
(8,9,
or IO wires) depends
on the applica-
tion. When EIA signal
requirements
are not
known,
connect
the 10 EIA signals
listed in
Paragraph
10.20.
Figures
7-25 and
7-30
provide
diagrams
for connecting
RS-232
cables
between
PDIU-Dls
and Toshiba
lap
top, and IBM, XT and AT PCs.
4) Set the PDIU-DI DIP switch (SW1 -1 - 4) for the
desired
application.
Figure
7-32 shows
the
DIP switch
locations
and Paragraph
10.30
describes
switch functions.
5) Access Program
20 to configure
the PDIU-DI
for DTE-type
connection
and Program
39 for
data button
assignments
of the digital
tele-
phone connected
to the PDIU-DI.
Program
20
l
The port number
entered
for the PDIU-DI
in Program
20 is the port number
of the
digital telephone
to which the PDIU-DI
is
connected.
l
LED 01: Should always be ON for PDIU-
DI ports.
l
LEDO2: Should be ON for PDIU-DI ports,
unless the PC user will never use DIU AT
commands
(other
than
ATDD,
ATDT,
and ATD) and never require the PDIU-DI
to send result codes to display on the PC
display screen.
Frequently,
it is difficult
to determine
the full extent
of these
INSTALLATION-PERIPHERALS
SECTION 100-816-207
MARCH 1993
requirements;
so it is recommended
to
turn LED 02 ON. See the Data interface
UserGuidefor
information
regarding
DIU
AT commands
and result codes.
LEDs
03 and
04: Should
be OFF for
PDIU-DI
ports.
LED 05: Should
be ON if the system
is
installed
behind
a PBX or Centrex
that
uses access
codes
to make
external
calls or to insert a pause following
DIU
access of an outside
line.
LEDs
17 w 20: Used to establish
data
security
groups.
PDIU stations
are only
allowed
to make calls to PDlUs
in the
same data group to which they are as-
signed.
Program
39
l
The following
data call buttons
can be
assigned digital telephones
equipped
with
PDIU-Dls:
Data
Call,
and Modem.
Assign
SD buttons
to data devices
as
required.
Do not assign DSS buttons
to
data devices;
DSS buttons
are used for
voice calls only.
10.50 PDIU-DS
to Printer
Installation
10.51 STRATA
DK8 and DK16 enables serial print-
ers (laser, dot matrix, orothertypes)
to be connected
to stand-alone
data interface
units (PDIU-DSs).
Digital
telephones
equipped
with
PDIU-Dls
can
share access to these printers.
Serial printers op-
erate as DCE or DTE devices,
depending
on the
vendor;
the PDIU-DS
can be connected
to either
type, since it can be configured
as a DTE or DCE
device.
(The
PDIU-DS
comes
from
the factory
configured
as a DCE device.)
Follow
the steps
below to install the PDIU-DS
to a serial printer.
NOTES:
1. Only serial printers
(not parallel)
that con-
form
to EIA RS-232
signaling
require-
ments can be connected
to PDIU-DSs.
2. In rare applications,
it may be desired
to
connectprinters
to PDIU-D/s.
Refer to the
printer's
installation
instructions.