PART II. DK16 PRINTED CIRCUIT BOARD
INSTALLATION
4 GENERAL
4.01
This chapter provides
procedures
for installa-
tion of STRATA DK16 system printed circuit boards
(PCBs) into the Base and Expansion
units. This
includes
installation
instructions,
optional
configu-
ration
information,
and wiring
and programming
considerations
for each PCB.
4.02 Be sure the power
supply
has been tested,
and the ground
has been checked.
(See Chapter
5,
Section
I for the power supply
and Chapter
3 for
grounding.)
4.03 It is recommended
to install the Base Unit
option
PCBs K4RCU
and/or
KSTU before
mount-
ing the Base KSU on the wall.
4.04
Begin Expansion
PCB installation
only after
completion
of Expansion
Unit installation
(see
Chapter
5, Section
I).
5 DK16 PCB INSTALLATION
CONSIDERATIONS
5.01 The STRATA
DK16 Base Unit comes
stan-
dard with eight digital telephone
circuits (ports) and
four CO line circuits. The digital circuits are inte-
grated
into the motherboard,
and the CO line cir-
cuits are on the KCOU which is attached
to the P6
and P7 connectors
on the motherboard.
The com-
mon control unit, like the digital telephone
circuits,
is built into the motherboard.
5.10 DK16 Base Unit PCBs
5.11 The Base Unit can support
an optional
KSTU
printed circuit board (PCB) which provides four stan-
dard telephone
circuits (ports). In addition, a K4RCU
PCB can be installed to receive DTMF tones, and
detect busy tone for Automatic
Busy Redial (ABR)
operation.
5.20 DK16 Expansion
Unit PCBs
5.21 The Expansion
Unit can support
a number
of
PCBs: it can support
a PCOU which provides
four
INSTALLATION-DK 16 KSU & PCB
SECTION 100-816-205
MARCH 1993
CO line circuits; one or two KCDUs which provide
two CO line circuits
and four digital
telephone
circuits (ports); a PDKU which provides
eight digital
telephone
circuits (ports); a PEKU which provides
eight electronic
telephone
circuits (ports); a PESU
which
provides
two standard
and four electronic
telephone
circuits (ports); a PSTU which provides
eight
standard
telephone
circuits
(ports);
and a
PIOU or PIOUS
which
both provide
a port for a
Station Message
Detail Recording
(SMDR) device,
an interface
for remote
maintenance,
and relay
control options.
5.22 The DK16 Expansion
Unit does not come from
the factory
with any PCBs installed.
Any of the
PCBs listed above can fit into any of the unit's four
universal
slots; however,
it is recommended
that
PCBs that support
electronic
or digital telephones
be installed
into Slots 04 and 05, because
Slots 06
and 07 cannot
support
Off-hook
Call Announce
or
Data Interface
Units (DIUs).
Recommended
PCB slot assignments:
KCDU -
Slot 04 and 05 (2 maximum)
PDKU, PEKU, PESU, PSTU -
Slot 04 (1 maxi-
mum, cannot
be installed
with KCDU.)
PCOU -
Slot 05 (1 maximum,
cannot
be in-
stalled with KCDU.)
PIOU/PIOUS
-
Slot 06 (1 maximum)
5.30 PCB Option
Considerations
5.31
PCBs
may
be configured
for a variety
of
hardware
and software
options.
Hardware
options
are defined
as either internal
(generally
related to
optional
PCB subassemblies)
or external
(related
to connection
of peripheral
equipment
such
as
background
music, voice mail, etc). Hardware
and
software
options for each PCB are identified
in the
individual
PCB installation
procedures
in this chap-
ter.
5.32 PCB Hardware
Options.
Each PCB must be
configured
for the applicable
hardware
options
prior to installation
of the PCB. Configuration
in-
structions
for internal
hardware
options
are pro-
vided in the individual
PCB installation
procedures
in this chapter.
Configuration
instructions
for exter-
nal hardware
options
are provided
in Peripheral
Installation,
Section
100-816-207.