Toshiba strata DK8 Installation Instructions Manual page 187

Hide thumbs Also See for strata DK8:
Table of Contents

Advertisement

2)
3)
4
l
Program
20: Port 04. LEDs 01, 02, 03,
04, 06, and 17 ON; all other LEDs OFF.
l
Program
21: Digital
port 04 assigned
with PSTU port 08.
l
Program 39:
Port 00. Data
Call
(56),
Data
Release
(54), and Modem
(55)
buttons
should be provided.
l
Program 81:
Port 08. LED 01 ON (CO
line 01 rings QSTWKSTU
port 08).
l
Internal
modem:
set to auto
answer
(SO=l).
l
Default
settings
for PDIU-DI
and PDIU-
DS, S-Registers.
Make sure PC 1 and PC 2 are on-line with a
communications
software
package
and that
the communication
parameters
of each PC
and communication
software
package
are set
to the same values
(data transmission
rate,
parity, data bits, stop bits, flow control,
etc.).
From PC 2's keyboard,
type
A
T D T 5 8 3
37
0
0
0
0
0
8
0 0 and press ENTER.
The external
modem
originates
the call
to STRATA
DK16 CO line 01.
CO line 01 rings incoming
to the internal
modem
(QSTU or KSTU port 08).
The internal
modem
rings and auto an-
swers; the modems
handshake
and es-
tablish communications.
If the modems
send
result codes,
the
PC'sscreensdisplay,
CONNECTXXXX,
where
XXXX
is the data transmission
speed
set by the communications
soft-
ware.
At this time, PC 2 is connected
to PDIU-
DS (14), as shown
by the thick
lines
above
(PDIU-DS
14 is in the command
mode).
PC 2 can now issue AT com-
mands to PDIU-DS
14.
If DigitaVPDIU-DS
port 04 is the only
PDIU port connected
to a modem
(Pro-
gram
20, LED 03 ON), then the Modem
LEDs on all DKTs will light.
From PC 2's keyboard,
type AT
D D 10 and
press ENTER
(AT commands
must be capi-
tal letters); this prompts
PDIU-DS
(14) to dial
and connect
to PDIU-DI
(10).
INSTALLATION-PERIPHERALS
SECTION 100-816-207
MARCH 1993
l
The CONNECT
LED on the PDIU-DS
(14) will be lit; the Data Call and Modem
LEDs on DKT 10 will also be lit.
l
The screens
on PC 1 and PC 2 display,
CONNECT
XXXX, where
XXXX is the
data transmission
speed set by the com-
munication
software.
l
At this time,
PC 1 and PC 2 are con-
nected,
as shown
by the thick lines, to
exchange
data (file transfers,
typed mes-
sages, etc.).
5) To terminate
the call: Press the telephone
Data
Release
button,
and
a) Type + + + from PC2 keyboard.
l
The PC screen displays,
OK.
b) Type A T H from the PC keyboard
used
in step 5a.
l
PC l's and PC 2's screens
both dis-
play, NO CARRIER.
l
The DATA
and MODEM
LEDs
on
DKT 10 will turn off.
10.86 PC Auto Dial Voice Call Test (see Figure
7-38)
There are many off-the-shelf,
IBM/MS-DOS
com-
patible, desktop
organizer
software
packages
that
provide an auto dialer function.
One of these is the
terminal
resident SideKick.
It is used in this section
for test explanation
purposes
only. If you choose
another
auto dialer software
package,
the detailed
response
may be different
than that shown
here.
1) DIU Programming:
Program
20: Port 01. LEDs 01,02,
and 17
ON; all other LEDs OFF.
Program
39: Port 01. Data
Call
(56) and
Data
Release
(54) buttons
are optional;
if
the PDIU-DI
is only used for the PC auto dial
application,
the
Data
Call
and
Data
Release
buttons
are unnecessary.
2) Make sure that the auto dial application
soft-
ware is installed
on the PC root directory
and
that the communication
parameters
of the
PC
and application
software
are set to the same
values
(in this
test
example,
Sidekick
"SKINSTAL"
program).
7-55

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata dk16

Table of Contents