4.11 Solenoid Replacement Procedure

The replacement solenoid (color of wiring:Orange) can be used for both solenoids of
Ink-side and makeup-side.
[Caution]
・Please do not mix up solenoid connectors of ink-side and makeup-side when you
connect them.
・After replacement, please cofirm that the solenoid on ink-side and/or Makeup-side
operates properly.
・Do NOT spill makeup over the solenoids.
Turn off the power supply.
Follow the procedures described in "4.1.2 Access to the parts on the front side of the
equipment" and pull the Reservoir unit out.
Remove the Fixing screw and remove Main ink tank.
[Caution] Be careful not to tip Main ink tank over.
Main ink tank
Fixing screw
Remove the fixing screws (2 positions) and remove the Makeup reservoir.
Remove the Solenoid cable from the hook on the Inner cover(B).
Hook
Solenoid cable
[Caution] Pay attention NOT to pinch the Solenoid Cable while above work is implemented.
Fixing screws
Makeup reservoir
Inner cover(B)
4-34