6.2.8 Makeup Replenishment Time-out
Makeup Replenishment
Time-out
Does the MV7 (Makeup valve)
operate on the solenoid
valve/pump test screen?
Yes
The makeup does not flow into
the main ink tank from the
makeup reservoir when Pump
and MV7 are operated on the
solenoid valve/Pump test screen
Yes
Refer to 4.14 Trouble shooting
Procedure for the Circulation System,
Probable cause : The makeup pump
malfunctions, and Then, repair or replace
Makeup Pump.
Does the initial-level
sensor operate?
No
Is CN13 of the EZJ126 board,
CN1 or CN3 of or EZJ132 board
disconnected?
No
Disconnect the connectors, then
reconnect them (3 connectors).
Does the Initial-level
sensor operate?
No
Is the connection harness
conducting?
Yes
Is the fault cleared by
power-on reset?
No
Replace the EZJ126 board.
[CAUTION]
If you remove the solenoid valve or other piping part without relieving the
pressure from the path, the ink may gush out. Before performing the above
steps, be sure to provide pressure relief.
No
Replace the connection
harness
No
Yes
Yes
Connect the connector.
Yes
No
Replace the harness.
Yes
6-12
Does the MV7 operate when
the connector of the other
operating solenoid valve is
Yes
connected to MV7?
Replace MV7 or clean any ink
build up or other foreign
matters on MV7.
Resume the
operation.