FLOOR TYPE
The drain hose can be connected at either side of the indoor unit.
The unit has been shipped with the drain hose connectedat left (viewed from the back of the
unit) and the drain cap applied at right.
Drain pan
Drain hose
Screw
Drain holder
Drain hose
Drain cap
OK
Stopping
downward
In order to align the drain hose and drain cap, be sure to insert securely and vertically.
Incline insertion will cause water leakage.
When inserting, be sure not to attach any material besides water. If any other material is
attached, it will cause deterioration and water leakage.
After removing drain hose, be sure not to forget mounting drain cap.
Be sure to fix the drain hose with tape to the bottom of piping.
Drain cap
Drain
hose
Drain pan
Drain cap
Screw
Drain holder
No upward
slope
50 mm or less
from ground
- (06 - 125) -
Installation method
of Drain cap
No gap
Hexagonal
wrench
prohibited
Accumulated
drain water
Air
No upward
slope
CAUTION
Drain Cock
Drain cap
End of drain hose
is immersed in
water
Drainage
channel
6. SYSTEM DESIGN