11.6 Device Range that Can Be Set

The device ranges of controller that can be used for GOT are as follows.
Note that the device ranges in the following tables are the maximum values that can be set in GT Designer3.
The device specifications of controllers may differ depending on the models, even though belonging to the same series.
Please make the setting according to the specifications of the controller actually used.
When a non-existent device or a device number outside the range is set, other objects with correct device settings may not
be monitored.
■1. Setting item
Item
Set the device name, device number, and bit number.
Device
The bit number can be set only when specifying the bit of word device.
Information
Displays the device type and setting range which are selected in [Device].
Set the monitor target of the set device.
Network
Station No.
11.6.1
GE Series 90
Device name
input (I)
output (Q)
internal (M)
temporary (T)
system status (S)
Bit device
system status (SA)
system status (SB)
system status (SC)
global data (G)
The bit specification of the word device
system register (R)
Word device
analog input register (AI)
analog output register (AQ)
Select this item when monitoring the PLC of the specified station No.
Description
Setting range
I00001 to I12288
Q00001 to Q12288
M00001 to M12288
T001 to T256
S001 to S128
SA001 to SA128
SB001 to SB128
SC001 to SC128
G0001 to G7680
Setting range of each word device
R00001 to R32640
AI0001 to AI32640
AQ0001 to AQ32640
11.6 Device Range that Can Be Set
Device No.
representation
11
Decimal
Decimal
11 - 17

Advertisement

Table of Contents
loading

Table of Contents