Unique Programming for Digital Pager Message Notification
1.
Set up the system-wide options that apply to the digital pager callback number.
Program
Program Name
Number
47-01-07
Digital Pager Callback Number
(Pager CBack)
47-01-08
Delay in Dialing Digital Pager
Callback Number
(Pager Dial Delay)
2.
Set up the system-wide options that apply to digital pager callouts.
Program
Program Name
Number
47-01-09
Wait Between Digital Pager
Callout Attempts
(Notify Pager Intvl)
47-01-15
Send Pager Callout Until Ac-
knowledged
(Retry Until Ack)
InMail Feature Manual
Description
Set the Digital Pager Callback Number portion of the Message Noti-
fication callout number for a digital pager. This is the portion of the
callout number that is appended to the pager service telephone
number.
By default, this option is X
*
• X is the number of the extension that generated the notification.
*
is a visual delimiter (to make the pager display easier to read).
• M is the number of new messages in the extension's mailbox.
• # is the digit normally used by the pager service for positive dis-
connect.
Set the delay (0 ~ 99 seconds) that occurs just before InMail dials
the Digital Pager Callback Number portion of the Message Notifica-
tion callout number for a digital pager. Set this delay so the pager
service has enough time to connect to the digital pager before send-
ing the callback number. Your pager service may be able to help
you determine the best value for this option (0 ~ 99 seconds). When
placing a digital pager notification, the system:
• Seizes the trunk specified by the Trunk Group Routing setup.
• Dials the user-entered notification number (in Message + OP +
N).
• Waits the 47-01-08 Delay in Dialing Digital Pager Callback Num-
ber interval.
• Dials the number entered in 47-01-07 Digital Pager Callback
Number.
The system assumes that the notification number completes dialing
approximately 4 seconds after trunk seizure. This means that, by
default, the Digital Pager Callback Number is
dialed into the pager service about 13 seconds after trunk seizure.
Your pager service may be able to help you determine the best val-
ue for this option.
By default, this option is 30 seconds.
Description
Set the minimum time (1 ~ 255 minutes) between unacknowledged
or unanswered digital pager Message Notification callouts. (A sub-
scriber acknowledges a digital pager notification by logging on to
their mailbox.) After this interval expires, InMail tries the callout
again (for up to the number of times set in 47-01-14 Number of Cal-
lout Attempts).
If the system dials the callout number and the pager service is busy,
it retries the number in one minute.
By default, this option is 15 minutes.
When this option is enabled (1), InMail continues to retry a digital
pager Message Notification callout until the notification is acknowl-
edged. If this option is disabled (0), InMail retries a digital pager
Message Notification the number of times specified in 47-01-14
Number of Callout Attempts. This option does not apply to Message
Notification callouts to telephone numbers.
A digital pager notification is acknowledged when the recipient logs
on to the mailbox.
By default, this option is disabled (0).