Chapter 2
Installing the Device
Figure 5: M23 Power Supply Connector
Terminal #
1
2
3
4
5
8
Description
Usage
PS1 Live / +
PS1 Live / + is connected to the positive (+) terminal if the power source is DC or
to the (Live) terminal if the power source is AC.
PS1 Neutral / -
PS1 Neutral / - is connected to the negative (-) terminal if the power source is DC
or to the (Neutral) terminal if the power source is AC.
Chassis Ground
Chassis Ground is connected to the Safety Ground terminal for AC inputs or the
equipment ground bus for DC inputs. This terminal 3 is connected to chassis
ground internally in the RS969 family. There is also an additional chassis ground
screw and the chassis ground connects to both power supply surge grounds via a
removable jumper shown in
PS2 Live / +
PS2 Live / + is connected to the positive (+) terminal if the power source is DC or
to the (Live) terminal if the power source is AC.
PS2 Neutral / -
PS2 Neutral / - is connected to the negative (-) terminal if the power source is DC
or to the (Neutral) terminal if the power source is AC.
Figure 6
.
Power Supply Input Connectors Description
RUGGEDCOM RS969
Installation Guide