Section 4.1
Power Supply Specifications
Power Supply Type
12–24 VDC
24 VDC
48 VDC
b
HI (125/250 VDC)
b
HI (110/230 VAC)
a
(T) denotes time-delay fuse.
b
This is the same power supply for both AC and DC.
Section 4.2
Failsafe Relay Specifications
Maximum Switching Voltage
30 VDC
125 VDC
125 VAC
220 VDC
250 VAC
Power Supply Specifications
Minimum Input
Maximum Input
10 VDC
36 VDC
18 VDC
36 VDC
36 VDC
72 VDC
88 VDC
300 VDC
85 VAC
265 VAC
Internal
Fuse Rating
3.15A (T)
3.15A (T)
3.15A (T)
ab
3.15A (T)
Rated Switching Current
2 A, 60 W
0.24 A, 30 W
0.5 A, 62.5 W
0.24 A, 60 W
0.25 A, 62.5 W
Technical Specifications
Isolation
a
1.5 kVDC
a
1.5 kVDC
a
1.5 kVDC
4 kVAC
5.5 kVDC
Isolation
1500 V
rms
Chapter 4
Max. Power
Consumption
10 W
for 1 minute