Iec Environmental Type Tests - Siemens RUGGEDCOM RS969 Installation Manual

Hide thumbs Also See for RUGGEDCOM RS969:
Table of Contents

Advertisement

Chapter 7
Certification
Section 7.4.3

IEC Environmental Type Tests

Table: Environmental Type Tests
Test
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-30
IEC 60255-21-1
IEC 60255-21-2
IEC 60529 (IPx6)
IEC 60529 (IPx7)
IEC 60529 (IP6x)
40
Description
Cold Temperature
Dry Heat
Humidity (Damp
Heat, Cyclic)
Vibration
Shock
Ingress Protection
Ingress Protection
Water Submersion
Ingress Protection
Test Levels
Test Ad
-40 deg. C, 16 Hours
Test Bd
+85 deg. C, 16 Hours
Test Db
95% (non-condensing),
55 deg. C, 6 cycles
2g @ (10-150) Hz
30g @ 11ms
Water Jet
100l/m @ 2.5m
as per 14.2.6
30 min @ 1m
as per 14.2.7
Dust Talcum
2kg/m3 for 8h as per 13.4
RUGGEDCOM RS969
Installation Guide
Severity Levels
N/A
N/A
N/A
Class 2
Class 2
N/A
N/A
Cat. 1&2