11.6

DME20 DRIVE-CLiQ Hub Module

Properties
The DME20 DRIVE-CLiQ Hub Module is used to implement point-to-point distribution of a
DRIVE-CLiQ line. With the DME20, an axis grouping can be expanded with 5 DRIVE-CLiQ
sockets for additional subgroups.
The component has degree of protection IP67 and is especially suitable for applications
which require DRIVE-CLiQ nodes to be removed in groups, without interrupting the DRIVE-
CLiQ line and therefore the data exchange.
The DME20 can be used with SINAMICS firmware version 2.6 or higher.
The cooling clearances of 50 mm above and below the component must be observed.
Additional references
You can find further information on the DME20 in the SINAMICS S120 manual titled "Control
Units and Additional System Components".
11.7

Ordering data

Table 11-13 Order data for system components
System components
NCU 710.2 with PLC 317-2DP
NCU 720.2 with PLC 317-2DP
NCU 720.2 PN with PLC 319-3PN/DP
NCU 730.2 with PLC 317-2DP
NCU 730.2 PN with PLC 319-3PN/DP
Numeric Control Extension NX15 (High Extension)
Numeric Control Extension NX10 (High Extension)
Dual fan/battery module
COM01.2 RS232C(V.24) module for NCU 7x0.2
TS Adapter IE ISDN with integrated ISDN terminal adapter
TS Adapter IE Modem with integrated analog modem
NCU
Manual, 03/2010, 6FC5397-0AP10-3BA0
CAUTION
Spare Parts/Accessories
11.6 DME20 DRIVE-CLiQ Hub Module
Order numbers
6FC5371-0AA10-0AA1
6FC5372-0AA00-0AA2
6FC5372-0AA01-0AA2
6FC5373-0AA00-0AA2
6FC5373-0AA01-0AA2
6SL3040-0NB00-0AA0
6SL3040-0NC00-0AA0
6FC5348-0AA02-0AA0
6FC5312-0FA01-0AA0
6ES7972-0ED00-0XA0
6ES7972-0EM00-0XA0