Dell DR4000 Administrator's Manual page 110

Disk backup appliance
Hide thumbs Also See for DR4000:
Table of Contents

Advertisement

FILE LOCATION: C:\Users\bruce_wylie\Documents\~Dell
Docs\~FINAL_DR4000_1.0.1.1_DOCS\~Final_1.0.1.1_DR4000_Admin_Guide_Files\~3-
Table 8-2. DR4000 System Event Messages
System Event Message
System Event = Type 1
DR4000 system has failed to
complete the basic system
initialization.
Unable to detect the filesystem type
on the New Space volume.
Name Space Volume is not
mounted.
DR4000 system failed to process
deleted files and containers.
Internal Failure processing the data
ingest log.
Hardware Health monitor database
is corrupted.
Unable to communicate with the
Hardware Health monitor.
Unable to communicate with the
NVRAM.
Capacitor is disconnected from the
NVRAM.
Solid-state drive (SSD) is
disconnected from the NVRAM.
NVRAM capacitor is not charging.
NVRAM failed to backup or restore
data during the last reboot.
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 4 / 5 / 1 2 - F O R P R O O F O N LY
102
Troubleshooting and Maintenance
Description/Meaning or Action
Contact Dell Support for support assistance or
intervention. For more information, see
"Initializing the DR4000 System" on page 13.
Collect a diagnostics log file, and contact Dell
Support for assistance or intervention.
Collect a diagnostics log file, and contact Dell
Support for assistance or intervention.
Contact Dell Support for support assistance or
intervention.
Contact Dell Support for support assistance or
intervention.
Contact Dell Support for support assistance or
intervention.
Reboot the DR4000 system. If issue persists,
contact Dell Support for assistance or
intervention.
Reboot the DR4000 system. If issue persists,
contact Dell Support for assistance or
intervention.
Contact Dell Support for support assistance or
intervention. If the problem persists after
reboot, replace the NVRAM.
Contact Dell Support for support assistance or
intervention. If the problem persists after
reboot, replace the NVRAM.
Contact Dell Support for support assistance or
intervention. If the problem persists after five
minutes of power shutdown, replace the
NVRAM.
Contact Dell Support for support assistance or
intervention.