After installing the riser card:
1. Refer to your note to reconnect any cables to the removed PCIe adapters.
2. Reinstall the PCIe adapters on the new riser card. See "Install a PCIe adapter on the riser assembly" on
page 154.
3. Install the riser assembly by doing the following:
• To install the riser 1 assembly, align the mounting stud on the system board with the corresponding
hole in the riser bracket. Meanwhile, align the rear of the riser 1 assembly with the corresponding rail
guides in the rear of the chassis. Then, carefully press the riser 1 assembly straight down into the
chassis until it is fully seated.
Figure 112. Riser 1 assembly installation
• To install the riser 2 assembly, align the rear of the riser 2 assembly with the corresponding rail guides
in the rear of the chassis. Then, carefully press the riser 2 assembly straight down into the chassis
until it is fully seated.