Name
Step control through
BYTE
digital input 3
Step control through
BYTE
digital input 4
Step control through
BYTE
digital input 5
Step control through
BYTE
digital input 6
Step control through
BYTE
digital input 7
Reserve 4
BYTE
Monitoring time step
TIME
control
SIWAREX FTA
Type
Address
Default
DBB042
0
DBB043
0
DBB044
0
DBB045
0
DBB046
0
DBB047
0
DBB048
0
Range of Values / Explanation
Instead of defined command codes for the digital
inputs, step-on conditions can be influenced
through the inputs for weighing control
(prerequisite in DR interface parameters is
identification 0xFF).
0: Weighing waits at step 0 if DI3 is active;
1: Weighing waits at step 1 if DI3 is active
2: Weighing waits at step 2 if DI3 is active
...
7: Weighing waits at step 7 if DI3 is active
Other definitions not permitted.
Instead of defined command codes for the digital
inputs, step-on conditions can be influenced
through the inputs for weighing control
(prerequisite in DR interface parameters is
identification 0xFF).
0: Weighing waits at step 0 if DI4 is active;
1: Weighing waits at step 1 if DI4 is active
2: Weighing waits at step 2 if DI4 is active
...
7: Weighing waits at step 7 if DI4 is active
Other definitions not permitted.
Instead of defined command codes for the digital
inputs, step-on conditions can be influenced
through the inputs for weighing control
(prerequisite in DR interface parameters is
identification 0xFF).
0: Weighing waits at step 0 if DI5 is active;
1: Weighing waits at step 1 if DI5 is active
2: Weighing waits at step 2 if DI5 is active
...
7: Weighing waits at step 7 if DI5 is active
Other definitions not permitted.
Instead of defined command codes for the digital
inputs, step-on conditions can be influenced
through the inputs for weighing control
(prerequisite in DR interface parameters is
identification 0xFF).
0: Weighing waits at step 0 if DI6 is active;
1: Weighing waits at step 1 if DI6 is active
2: Weighing waits at step 2 if DI6 is active
...
7: Weighing waits at step 7 if DI6 is active
Other definitions not permitted.
Instead of defined command codes for the digital
inputs, step-on conditions can be influenced
through the inputs for weighing control
(prerequisite in DR interface parameters is
identification 0xFF).
0: Weighing waits at step 0 if DI7 is active;
1: Weighing waits at step 1 if DI7 is active
2: Weighing waits at step 2 if DI7 is active
...
7: Weighing waits at step 7 if DI7 is active
Other definitions not permitted.
Reserve 4
0: No monitoring
>0 Time definition for the monitoring
If no further stepping to the next weighing step is
performed within the defined time then the "Step-
on Timeout" technology error is generated.
Weighing Functions
Reference
5.16.16
5.16.16
5.16.16
5.16.16
5.16.16
5.16.17
5-97