Code
Command explanation
Residual weighing
110
If required, a running weighing procedure is
stopped and the emptying process is started
immediately. The current weight is balanced before
emptying. In certain cases, continuous operation is
ended.
111
Activate inhibition time
The weight value is not determined for a configured
time period. Furthermore, the measurement value
error (operating error 17) is suppressed during this
period. The defined time can be shortened and
thus the inhibition time ended immediately using
command 112.
Deactivate inhibition time
112
The activated inhibition time is stopped
prematurely.
113
Logging and deleting calibratable totalizing
memory 1
This command is only executed if total 1 is
contained in log text 1.
Deletes totalizing memory 1
114
Permitted only if country code is not "OIML"
Deletes totalizing memory 2
115
Totalising memory 2 can be deleted at any time.
SIWAREX FTA
Commands
Executable
in following
operating
states
Stopped, Dosing
cycle
All
All
No weighing
cycle
No weighing
cycle
No weighing
cycle