Mitsubishi Electric FR-A820-00046 Instruction Manual page 182

Fr-a800 series
Hide thumbs Also See for FR-A820-00046:
Table of Contents

Advertisement

Frequently-used parameters (simple mode parameters)
Pr.
Pr.
group
7
F010
8
F011
H000
9
C103
79
D000
125
T022
126
T042
160
E440
998
E430
999
E431
Tab. 4-9:
Initial value for the FR-A820-00077(0.75K) or lower and FR-A840-00038(0.75K) or lower.
Initial value for the FR-A820-00105(1.5K) to FR-A820-00250(3.7K) and the FR-A840-00052(1.5K) to
FR-A840-00126(3.7K).
Initial value for the FR-A820-00340(5.5K), FR-A820-00490(7.5K), FR-A840-00170(5.5K), and
FR-A840-00250(7.5K).
Initial value for the FR-A820-00630(11K) to FR-A820-03160(55K), FR-A840-00310(11K) to
FR-A840-01800(55K).
Initial value for the FR-A820-03800(75K) or higher and FR-A840-02160(75K) or higher.
For the FR-A820-03160(55K) or lower and FR-A840-01800(55K) or lower.
For the FR-A820-03800(75K) or higher and FR-A840-02160(75K) or higher.
The initial value for the FR-A820-00077(0.75K) or lower and FR-A840-00038(0.75K) or lower is set
to the 85% of the inverter rated current.
Initial value for the FR-A820-00490(7.5K) or lower and FR-A840-00250(7.5K) or lower.
Initial value for the FR-A820-00630(11K) or higher and FR-A840-00310(11K) or higher.
FM denotes the initial value for the FM type inverter that has the terminal FM, and CA denotes the
initial value for the CA type inverter that has the terminal CA.
4 - 12
Initial value
Name
Unit
FM
Acceleration time
0.1 s
Deceleration time
0.1 s
0.01 A
Electronic
thermal O/L relay
0.1 A
Operation mode
1
selection
Terminal 2
frequency setting
0.01 Hz 60 Hz 50 Hz 0–590 Hz
gain frequency
Terminal 4
frequency setting
0.01 Hz 60 Hz 50 Hz 0–590 Hz
gain frequency
User group read
1
selection
PM parameter
1
initialization
Automatic
1
parameter setting
Simple mode parameters (2)
Range
Application
CA
5 s
0–3600 s
Sets the acceleration time.
15 s
5 s
0–3600 s
Sets the deceleration time.
15 s
0–500 A
Rated
Protects the motor from heat.
inverter
Set the rated motor current.
0–3600 A
current
Select the start and frequency command
0
0–4, 6, 7
sources.
Allows the frequency at the maximum
potentiometer setting (5 V in the initial
setting) to be changed.
Allows the frequency at the maximum
current input (20 mA in the initial setting)
to be changed.
Restricts the parameters that are read by
0
0, 1, 9999
the operation panel and parameter unit.
0, 3003,
3103,
Selects the PM sensorless vector control
0
8009,
and set the parameters that are required to
8109,
drive an PM motor.
9009, 9109
Changes parameter settings as a batch.
The target parameters include
1, 2, 10, 11,
communication parameters for the
12, 13, 20,
9999
Mitsubishi's human machine interface
21, 30, 31,
(GOT) connection and the parameters for
9999
the rated frequency settings of 50 Hz/
60 Hz.
Basic operation
Refer
to
page
5-241
5-303
5-271
4-27,
5-418
4-29,
5-418
5-224
5-75
5-219

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents