(F) Setting of acceleration/deceleration time and acceleration/deceleration pattern
Start-time hold function (Pr. 571)
● This function holds 0.01 Hz during the period set in Pr. 571.
● Pr. 71 is active when the low-speed range high-torque characteristic is enabled (Pr. 788 = "9999").
Output
frequency
[Hz]
CAUTION:
E
Note that when Pr. 13 is set to any value equal to or lower than Pr. 2 "Minimum frequency",
simply turning ON the start signal will run the motor at the frequency set in Pr. 2 even if the
command frequency is not input.
Parameters referred to
Pr. 2
Pr. 7
5 - 262
60
0
Holds 0.01 Hz
Pr. 571 setting time
ON
STF
Minimum frequency
Acceleration time
Fig. 5-106:
Function of start-time hold function
Time
Parameters
I002832E
=>
page 5-321
=>
page 5-241