Pulse Encoder Insulation (Acp 600); Installation Of Optional Modules And Drivewindow - ABB ACS 601 Hardware Manual

Ac drives, 3 to 150 hp, 2.2 to 110 kw
Hide thumbs Also See for ACS 601:
Table of Contents

Advertisement

Chapter 3 – Electrical Installation
Pulse Encoder
Insulation (ACP 600)
Installation of
Optional Modules and
DriveWindow
Placement
Power Supply
for the Module
Fiber Optic Link
3-10
ACx=ACS/ACC/ACP
The pulse encoder shall be insulated electrically from stator or rotor to
prevent forming of current path through the pulse encoder. The usual
coupling-type encoder must have an electrically insulating coupling.
When a hollow-shaft type pulse encoder is used, the insulation can be
implemented by insulating the ball joints of the engaging arm, or
insulating the bar of the engaging arm. Shield of the encoder cable
should be insulated from the encoder frame. See Appendix B for
grounding of the other end of the encoder cable shield.
This section gives general installation instructions for Drive Window PC
tool and ACx 600 optional modules, such as fieldbus adapters, I/O
extension modules and the pulse encoder interface. Connection
examples are given at the end of the section.
The module should be installed inside the unit on the location shown in
the dimensional drawings ( Appendix B ). Option modules for the frame
sizes R2 and R3 are installed outside the frequency converter. Follow
the instructions given in the Mechanical Installation chapter of the
module manual.
The 24 V d.c. supply for one optional module is provided by the NIOC/
NIOCP board of the converter (NIOC: terminal X23, NIOCP: terminal
X4). The location of the NIOC/NIOCP board is shown in the
dimensional drawings ( Appendix B ).
Optional modules are connected via a DDCS fiber optic link to the
NAMC board or NDCO board (both mounted on top of the NIOC
board). The terminals on the NAMC/NDCO board to which the cables
are connected are given in the table below. Channel CH1 is on
NAMC-11 board. Channels CH0, CH2 and CH3 are on NDCO board.
NAMC-3 board includes channels CH0 to CH3.
Module Type
Fieldbus Adapter Modules
I/O Extension Modules
Pulse Encoder Interface Module
Double Pulse Encoder Interface
Module (for ACP 600 only)
Drive Window
* on NDCO board when NAMC-11 board is used.
Observe color codes when installing fiber optic cables. Blue connectors
should go to blue terminals, and grey connectors to grey terminals.
In case multiple modules are installed on the same channel, they must
be connected in a ring.
Channel
CH0*
CH1
CH2* with ACS 600
Standard Application
Program 5.0
CH1 with ACS 600 Crane
Application Program 5.x
CH2*
CH3*
ACS/ACC/ACP 601 Drives
Terminals
V13*, V14*
V15, V16
V17*, V18*
V15, V16
V17*, V18*
V19*, V20*

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acc 601Acp 601Acs 600

Table of Contents