ABB ACS 601 Hardware Manual page 46

Ac drives, 3 to 150 hp, 2.2 to 110 kw
Hide thumbs Also See for ACS 601:
Table of Contents

Advertisement

Appendix A – ACS/ACC/ACP 601 Technical Data
Rating table continued
Pump and Fan Use
(Squared Load)
ACx 601
I
2Nsq
Type
[A]
[kVA]
Three-phase supply voltage 380 V, 400 V or 415 V
ACx 601-0005-3
7.6
ACx 601-0006-3
11
ACx 601-0009-3
15
ACx 601-0011-3
18
ACx 601-0016-3
24
ACx 601-0021-3
41
ACx 601-0026-3
47
ACx 601-0031-3
62
ACx 601-0041-3
76
ACx 601-0051-3
89
ACx 601-0061-3
112
ACx 601-0071-3
124
ACx 601-0101-3
178
ACx 601-0121-3
200
Three-phase supply voltage 380 V, 400 V, 415 V, 440
V, 460 V, 480 V or 500 V
ACx 601-0006-5
7.6
ACx 601-0009-5
11
ACx 601-0011-5
15
ACx 601-0016-5
18
ACx 601-0020-5
24
ACx 601-0026-5
41
ACx 601-0031-5
47
ACx 601-0041-5
58
ACx 601-0051-5
65
ACx 601-0061-5
84
ACx 601-0071-5
112
ACx 601-0101-5
124
ACx 601-0121-5
164
ACx 601-0141-5
200
Normal use (10 % overload capacity):
I
rated RMS output current
2N
I
short term rms overload current (allowed
2Nmax
for one minute every 10 minutes).
S
rated apparent output power
N
P
typical motor power. The power ratings in
N
kW apply to most IEC 34 motors. The
power ratings in HP apply to most four pole
NEMA rated motors.
A-2
ACx=ACS/ACC/ACP
S
P
P
N
N
N
Frame
SIze
[kW]
[HP]
5
3
3
R2
6
4
5
9
5.5
7.5
11
7.5
10
R3
16
11
15
20
15
20
R4
25
18.5
25
30
22
30
R5
40
30
40
50
37
50
60
45
60
R6
70
55
75
100
75
100
R7
120
90
125
6
4
5
R2
9
5.5
7.5
11
7.5
10
16
11
10
R3
20
15
15
25
18.5
20
R4
30
22
30
40
30
30
R5
50
37
40
60
45
50
70
55
60
R6
100
75
75
120
90
100
R7
140
110
125
Pump and Fan use (squared load): no overload capacity
I
rated RMS output current
2Nsq
S
rated apparent output power
N
P
typical motor power. The power ratings in
N
kW apply to most IEC 34 motors. The
power ratings in HP apply to most four pole
NEMA rated motors.
Current ratings are for drives in IP 20/21
enclosures. For drives in IP 54 enclosures,
see page A-4. For output current
temperature derating, see page A-3.
The current ratings are the same regardless
of the supply voltage within one voltage
range. The rated current of the ACx 60x
must be higher than or equal to the rated
motor current to achieve the rated motor
power given in the table .
Note 1: The maximum allowed motor shaft
power is limited to 1.5 · P
exceeded, the motor torque and the I
2 s current is automatically restricted. The
function protects the input bridge of the
ACS 600 against overload.
Note 2: The load capacity (current and
power) decreases if the installation site
altitude exceeds 1000 meters (3300 ft.), or
if the ambient temperature exceeds 40 °C
(104 °F(35 °C/95 °F for ACx 601-0120-03
units).
Note 3: The Pump and Fan rating is not to
be used with du/dt filters.
Usually dv/dt filters are needed at the
output of 525 V to 690 V units with random
wound motors. No dv/dt filters are usually
required with form wound motors.
Heavy-duty use (50 % or 100 % overload capacity):
I
rated RMS output current
2hd
I
rms overload current (allowed for one
2hdmax
minute every 10 minutes or 2 seconds
every 15 seconds) Maximum current
depends on parameter setting, refer to
Firmware Manual.
S
rated apparent output power
hd
P
typical motor power. The power ratings in
hd
kW apply to most IEC 34 motors. The
power ratings in HP apply to most four pole
NEMA rated motors..