Appendix A – ACS/ACC/ACP 601 Technical Data
External Control
Connections (NIOCP)
A-8
ACx=ACS/ACC/ACP
External control connections of ACP 600 with NIOCP board are below.
Terminal Block X1
1
+10 V
2
AGND
3
–10 V
4
AI1+
5
AI1–
6
AI2+
7
AI2–
8
AO1+
rpm
9
AO1–
Terminal Block X2
1
DI1
2
DI2
3
DI3
4
DI4
5
DI5
6
DI6
7
DI7
8
DI8
9
DI9
10
DI10
11
DI11
12
DI12
13
+24 DV
14
+24 DV
15
+24 DV
16
DGND
Terminal Block X4
1
+24 V
2
DGND
Terminal Block X5
1
+24 DV
2
DO1
3
DO2
4
DO3
5
DO4
6
DGND
Terminal Block X7
1
RO1 NCC
2
RO1 CM
3
RO1 NOC
Terminal Block X8
1
UENC+
2
SENSE+
3
SENSE–
4
UENC–
5
A+
6
A–
7
B+
8
B–
9
Z+
10
Z–
Function
Reference Voltage +10 VDC
2 kΩ ≤ R
Analog Ground
max. 10 mA
Reference Voltage –10 VDC
External Reference 1: Speed
Analog input signals 1 and
Reference
2, signal level ±10 V, input
impedance ≥ 20 kΩ,
External Reference 2: Not
resolution 12 bit
defined
Signal level ±10 V,
SPEED ACT 1
R
resolution 8 bit
START/STOP
RAPID STOP NOT
FAULT RESET
SPEED REF SWITCH
12 digital inputs for different
ACC/DEC 1/2 SEL
control configurations.
Signal level 24 VDC, typical
input current 8 mA, opto-
isolated as a group,
≤ 8 V = "0"; ≥ 12 V = "1"
Not defined
+24 VDC,
Control Voltage Output
total max 135 mA
Digital Ground
Auxiliary Voltage Output
+24 V
0 V
Control Voltage Input
ACT SPEED=0
Voltage 24 V, current 10 mA
each (internal supply) and
RUNNING
100 mA each (external
FAULT (-1)
supply), optoisolated as a
ACT SPEED=REF
group,
≤ 8 V = "0"; ≥ 12 V = "1"
Digital Ground
Max. switching voltage 120
VDC/250 VAC, max
1 Relay Output, READY Signal
switching current/power 2 A
at 24 VDC or 250 VAC, 0.4
A at 120 VDC, 500 VA
Power Supply
SUBD X6:4
Sense+
SUBD X6:5
Sense–
SUBD X6:13
0 V
SUBD X6:12
Channel A+
SUBD X6:1
Channel A–
SUBD X6:9
Channel B+
SUBD X6:2
Channel B–
SUBD X6:10
Channel Z+
SUBD X6:3
Channel Z–
SUBD X6:11
ACS/ACC/ACP 601 Drives
Specifications
≤ 10 kΩ
LOAD
≥ 1 kΩ ,
LOAD