Extending/Removing The Server Enclosure Out Of The Rack; Preliminary Steps - Fujitsu PRIMERGY CX400 M4 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY CX400 M4:
Table of Contents

Advertisement

Basic hardware procedures
4.4
Extending/removing the server enclosure
out of the rack
V
CAUTION!
Use the anti-tilt plate to prevent the rack from tipping when installing
the rack. Pulling the server out of the rack without having installed the
anti-tilt plate may cause the rack to tip over.
Be careful not to pinch fingers or clothes when sliding out the server
enclosure or pushing it back. Failure to do so may cause injury.
For further safety information, please refer to chapter
information" on page
I
In most cases maintenance tasks can be performed while the server
is extended from the rack. However, depending on accessibility or
security guidelines, it may make sense to completely remove the
server from the rack cabinet for maintenance purposes.
4.4.1

Preliminary steps

"Shutting down the server node" on page 40
Ê
"Disconnecting the power cord" on page 41
Ê
Ê If applicable, disconnect all external cables.
Ê If you remove the CX400 M4 server enclosure out of the rack, remove all
server nodes, PSUs, HDDS/SSDs from the server enclosure, see sections
"Removing server nodes from the server enclosure" on page
the hot-plug PSU" on page 84
module" on page
42
25.
and
"Removing a 2.5-inch HDD/SSD dummy
96.
Upgrade and Maintenance Manual
"Important
46,
"Removing
CX400 M4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents