Advertisement

7.4

[5] Safety

7.4.1

Assigning/changing PIN

Procedure
1. Main menu > "5. Security" > "2. Access management"
2. Assign/change passwords:
Quick Start
Compact Operating Instructions, 01/2013, A5E31805656-01
The parameter display includes parameter fields that you use to specify the PINs of the
permission levels.
The table below summarizes the assignment/change options:
Permission level
Parameter fields that require a higher permission level are locked.
1)
– Select the required permission level.
– Open the parameter field.
Authorize access by input of the corresponding PIN.
Use the following PIN for the corresponding permission levels during initial
commissioning: Standard: 1111, Expert: 2222.
– Enter new four-digit password in the "PIN" editing window.
The editing window is closed after the input.
Assignment/change options
Standard →
Expert →
Service →
Standard, Expert, and Service
Commissioning
7.4 [5] Safety
1)
Standard only
Standard and Expert
49