Installation

10.2 Instructions regarding the installation

10.2.1 Degree of protection through the housing (IP code)

®
The METPOINT
BDL compact data logger meets the requirements of the IP 44 degree of protection
in accordance with EN 60529.
The degree of protection of a housing is defined by the IP code and a two-digit code number. The first
digit includes the protection for persons and resources while the second digit only refers to the protection
against water.
IP 44 in accordance with EN 60529
IP
International Protection
4
Protected against the access to dangerous parts with a wire, Ø 1.0 mm
Protected against solid foreign particles with a Ø > 1.0 mm.
4
Protected against splash water
Water splashing against the housing from any direction must not have harmful effects.
DANGER!
Subsequent to all installation and service measures at the data logger, the indicated de-
gree of protection must be re-established and guaranteed
During the implementation of any works on the METPOINT
the following points:
Use original seals only. These must be clean and free from any damage. Defective seals need
to be replaced.
The electrical connecting cables must be free from damage.
The cables need to meet the requirements of the respective standards and provisions.
Defective connecting leads need to be replaced immediately.
The cables must be installed in the form of a loop in front of the measuring device in order to
prevent water from entering the housing.
Ensure that the cable glands are tightened firmly.
Threaded cable connections which are not used, need to be closed with a blank plug.
METPOINT® BDL compact
.
®