HP 53132A Assembly And Service Manual page 113

225 mhz counter
Hide thumbs Also See for 53132A:
Table of Contents

Advertisement

Chapter 2 Service
The HP 53131A/132A Calibration Procedures
6
Press Enter key.
The Counter momentarily displays CALIBRATING , and then it should
display OFFS 1 PASS .
If the fail message is displayed, refer to the troubleshooting section in this
chapter.
7
To calibrate Channel 2, press any one of the arrow keys until
CAL: OFFS 2 ? is displayed.
8
Press Enter key.
A scrolling message on the display will ask you to remove any signals
connected to Channel 2. Follow the instruction.
9
Press Enter key.
The Counter momentarily displays CALIBRATING , and then it should
display OFFS 2 PASS .
If the fail message is displayed, refer to the troubleshooting section in this
chapter.
This completes the Offset Calibration procedure. Proceed to the next
procedure to calibrate the gain.