Advanced circular chart recorder
Linearizer Type
Minimum
Type K
Types R & S
Type T
Type J
Type E
Type N
Type B
Rtd
Performance accuracy is not guaranteed below 400°C (725°F) for types B, R and S thermocouples.
Minimum span below zero for Type T thermocouples is 70°C (126°F).
Minimum span below zero for Type N thermocouples is 105°C (189°F).
THC standard DIN 4730 IEC 584.
RTD standard DIN 43760 IEC 751.
Linearizer Type
Square Root
3/2
5/2
None
Table 3.2 Limits of Engineering Ranges
28
Engineering Range High
Set the maximum engineering value required, within the limits shown in Table 3.2.
Engineering Range Low
Set the minimum engineering value required, within the limits shown in Table 3.2.
Chart Range High
Set the maximum value, in engineering units, required on the chart.
Note. If the Engineering Range High setting is changed, the Chart Range High setting is reset
automatically to the same value.
Chart Range Low
Set the minimum value, in engineering units, required on the chart.
Note. If the Engineering Range Low setting is changed, the Chart Range Low setting is reset
automatically to the same value.
Continued on next page.
Degrees Celsius
Maximum
–100
1300
–18
1700
–250
300
–100
900
–100
900
–200
1300
–18
1800
–200
600
Minimum
–999
Minimum Span
Minimum
65
–148
320
0
60
–418
50
–148
45
–148
90
–328
710
0
25
–328
Engineering Range High and Low
3 Configuration
Degrees Fahrenheit
Maximum
Minimum Span
2372
117
3092
576
572
108
1652
90
1652
81
2372
162
3272
1278
1112
45
Maximum
9999