Module Connections; Standard I/O Or Analog + Relay (Module Types 1, 2 And 7); Four Relay Module (Module Type 3); Eight Digital Inputs Or Outputs (Module Types 4 And 5 Respectively) - ABB C1300 User Manual

Advanced circular chart recorder
Hide thumbs Also See for C1300:
Table of Contents

Advertisement

C1300
Advanced circular chart recorder

5.3 Module Connections

5.3.1 Standard I/O or Analog + Relay
(Module Types 1, 2 and 7)
The connections are the same as Channel connections to the
main board. Refer to Section 5.2.

5.3.2 Four Relay Module (Module Type 3)

1
1
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
10
10
11
11
12
12
Fig. 5.6 Four Relay Module Connections (Module Type 3)
Notes.
1. Fuse rating – 500mA (20 X 5mm) Type T.
2. Ensure that the Earth (Ground) lead is longer than
the Line and Neutral leads.
70
Normally Closed
Normally Closed
Normally Open
Normally Open
Relay 1
Relay 1
Common
Common
Normally Closed
Normally Closed
Normally Open
Normally Open
Relay 2
Relay 2
Common
Common
Normally Closed
Normally Closed
Normally Open
Normally Open
Relay 3
Relay 3
Common
Common
Normally Closed
Normally Closed
Normally Open
Normally Open
Relay 4
Relay 4
Common
Common
5.3.3 Eight Digital Inputs or Outputs
(Module Types 4 and 5 respectively)
A plug-in link is used to select the board's function; digital inputs
or digital outputs – see Fig. 5.7. The maximum current drain
from each TTL output must not exceed 5mA.
PL2
PL2
3
2
3
4
1
4
Digital Inputs
Digital Outputs
Fig. 5.7 Selecting the Digital Module Function
(Module Types 4 and 5)
1
2
3
4
5
6
7
8
9
10
11
12
Connections
Fig. 5.8 Eight Digital Inputs or Outputs Connections
(Module Types 4 and 5)
5 Electrical Installation
PL2
4
1
2
1
Common
Common
Input 1
Output 1
Input 2
Output 2
Input 3
Output 3
Input 4
Output 4
Input 5
Output 5
Input 6
Output 6
Input 7
Output 7
Input 8
Output 8
Common
Common
Input
Output
or
Connections
IM/C1300 Rev. J

Hide quick links: