Removing A Compute Or Storage Sled From The Enclosure - Dell EMC PowerEdge MX7000 Installation And Service Manual

Hide thumbs Also See for EMC PowerEdge MX7000:
Table of Contents

Advertisement

Figure 14. Installing a sled blank

Removing a compute or storage sled from the enclosure

Prerequisites
1
Follow the safety guidelines listed in
2
Power off the sled.
CAUTION:
Ensure the compute sleds mapped to the storage sleds are powered off.
CAUTION:
Remove the storage sled only when the hard drive LED is
off.
NOTE:
If the storage sled drive LED indicator is off, it indicates that all the compute sleds mapped to the storage sled are
powered off.
NOTE:
If there are two Fabric C SAS IOMs in powered on state, the management module in the enclosure powers on the
storage sleds automatically.
Steps
1
To remove a storage or compute sled:
NOTE:
The procedure to remove a single-width and double-width compute sled is the same.
For a storage sled,
a
Open the sled removal hatch on the front panel of the sled.
b
To release the sled release lever, push the blue release button to the unlock position.
For a compute sled,
28
Installing and removing system components
Safety
instructions.

Hide quick links:

Advertisement

Table of Contents
loading