Chassis weight
Table 13. Chassis weight
Enclosure
PowerEdge MX7000
Fan specifications
The PowerEdge MX7000 enclosure supports four front accessible hot-swap cooling fans and five rear accessible hot-swap cooling fans.
The cooling fan assembly ensures that the key components of the server such as the sleds, Fabrics, and I/O modules get adequate air
circulation to keep them cool. A cooling fan failure can result in overheating and may lead to damage.
Table 14. Supported fans
Fan location
Size
Number of fans
Redundancy
PSU specifications
The PowerEdge MX7000 enclosure supports up to six AC power supply units (PSUs).
Table 15. PSU specifications
Description
PSU
Class
Heat dissipation (maximum)
Frequency
Voltage
Current
Inrush current
Connector
CAUTION:
Mixed high line and low line AC inputs in the same enclosure is not supported. If this occurs, the enclosure disables
the PSUs with the lowest input. If there is an equal number of high lines, and low line PSUs the high line PSUs are enabled.
NOTE:
Heat dissipation is calculated using the PSU wattage rating.
NOTE:
In an ideal input voltage condition and over the entire enclosures ambient operating range, the inrush current may reach
120 A per power supply for 10 ms or less.
NOTE:
This enclosure is also designed to connect to the IT power enclosures with a phase-to-phase voltage not exceeding 240
V.
Minimum weight
82 kg (180 lbs)
Front
60 mm
4
3+1
Maximum weight (fully populated)
182 kg (400 lbs)
Rear
80 mm
5
4+1
Specification
6 x 3000 W AC
Platinum
1205 BTU/hr
50/60 Hz
100–240 V AC, autoranging
6 x 16 A
120 A per power supply for 10 ms or less.
C22 AC power connector
Technical specifications
57