Sharp JW-21MN User Manual page 70

Me-net module
Table of Contents

Advertisement

From the previous page
Set top address of register link area on slave station 01 to 77
of offset bytes (at save memory function)
Set in parameter addresses 004404 to 004777
resister link area, flag area, or any area used by other option module.
004404
(8)
Slave
004405
(8)
station
004406
(8)
01
004407
(8)
004774
(8)
Slave
004775
(8)
station
004776
(8)
77
(8)
004777
(8)
- In case of setting 0 (the top address is コ0440, the same as the address of the master station) in
parameter addresses 004404 to 004407
"offset valid" on the parameter address 004410 to 004413
Slave
station
(Word display)
01
(Word display)
(Word display)
Slave
station
02
(Byte display)
Screen display of JW-14PG
04011
04012
I PARAM.
>04013
Set the number of sending bytes of the master station relay link [DCM (decimal), word]
Set in parameter addresses 005000 to 005001
005000
(8)
005001
(8)
These top addresses should not overlap the resister link area, or the flag area, or exceed the setting
range (0 to 256 bytes for each station, 256 bytes for all stations in total).
- In case of setting 8 bytes (Example for page 11-10)
Screen display of JW-14PG
04774
04776
I PARAM.
>05000
To the next page
In case of standard function, set top address by file address
Lower
Upper
In case of save memory function, set number of offset bytes.
File number
·
00
: The top address is the same address of the master station
(H)
regardless of the values set at of 004404 to 004405
80
: The top address is different from the address of the master
(H)
Lower
station (Offset is valid).
Upper
For the save memory function, set in 80
File number
·
00
(H)
80
(H)
(slave station 01) and the offset byte number 8 and
(8)
Write 0 in parameter 004004 to 004007
master station).
Write 80
HEX
00
HEX
00
HEX
80
(8)
Lower
Upper
Display the contents of parameter addresses 005000 to 005001
Write 00008
after converting to decimal.
(D)
D
00000
D
00000
D
00008
11-17
(at standard function)/number
(8)
. These top addresses should not overlap the
(8)
(slave station 02). (Example for 11-10)
(8)
Write 00010
(offset 8) in parameter
(D)
addresses 004410 to 004411
Write 000
(file 0) in parameter address 004412
(H)
(offset valid) in parameter address 004413
(H)
004404
(8)
Slave
004405
(8)
station
004406
(8)
01
004407
(8)
004410
(8)
Slave
004411
(8)
station
004412
(8)
02
004413
(8)
.
005000
(8)
005001
(8)
.
(8)
.
(8)
.
(H)
(same as
(8)
.
(8)
.
(8)
.
(8)
0000
(H)
00
(H)
00
(H)
00008
(D)
00
(H)
80
(H)
(8)
00008
(D)
11

Advertisement