Due to the weight of the unit, we highly recommend using these rails to mount the unit. This unit is not
suitable for mounting in racks with obstructions (such as a power strip) that could impair access to the
device. The air space in the front and rear of system should be 6.00 inches minimum.
Caution: Ground the chassis properly with the supplied power cord.
Caution: Be sure to position the power cord so that you can easily disconnect the chassis.
Caution: Do not install the chassis in an environment where the operating temperature might exceed
°
°
10
C (104
F)
.
Caution: Do not restrict air flow around the side and rear of the chassis. The air space in front and rear
of system should be 6.00 inches minimum.

Connecting Power to the Chassis

Follow these steps to connect power to the chassis:
Step 1.
Before you connect the power supply to a power source, ensure that all site power and grounding
requirements listed in "Site Power Requirements, Temperature and Heat Dissipation
Parameters" on page 2-6 have been met.
Step 2.
Plug the power cord into the rear of the chassis.
Step 3.
Connect the other end of the power cord to an AC-power input source.
Caution: Ground the chassis properly with the supplied power cord.
Step 4.
Be sure to position the power cord so that you can easily disconnect it from the chassis.
ProCurve Secure Access 700wl Series Installation and Getting Started Guide
Hardware Installation
2-7