Table 8- 3
p2051[x]
Index
0...5 here remain free, as they are already assigned by DO2.
1)
Table 8- 4
p2051[x]
Index
0...11 here remain free, as they are already assigned by DO2 and DO3.
2)
Send slots PZD 16 to 31 are not required for this telegram and are therefore filled with a
zero.
1. For double words (e.g. 1 + 2), assign two consecutive send slots, e.g.
p2061[1] => p8871[1] = PZD 2 and p8871[2] = PZD 3.
2. Enter the following PZD into the next parameter slots of p2051[x] or p2061[2x].
3. You must fill the unused slots of p8871[0...31] with zeros.
4. The sequence of the PZDs in the send telegram of this node are defined in parameter
p8871[0...31] by the entries in the required slots.
Communication
Function Manual, 12/2018, 6SL3097-5BD00-0BP0
Compile send data of drive 2 (DO3)
p2061[x]
Contents
Index
-
-
-
0
-
-
1
-
Actual speed value part 2
-
3
-
Actual torque value part 2
5
-
6
-
0
...
...
15
-
0
...
-
...
31
-
0
Compile send data of Control Unit 1 (DO1)
p2061[x]
Contents
Index
-
-
-
0
-
Control word, faults/alarms
-
1
Missing enables part 1
-
Missing enables part 2
15
-
0
...
-
...
31
-
0
Communication via SINAMICS Link
8.3 Configuring and commissioning
Slots in the send buffer
p8871[x]
x
-
0...5
1)
r0899
6
r0061[0]
7
8
r0080
9
10
r2131
11
0
12
...
0
15
-
...
0
31
From pa-
Slots in the send buffer
rameter
p8871[x]
x
-
0...11
2)
r2138
12
r0046
13
14
0
15
-
...
0
31
Telegram
word
0
7
8
9
10
11
12
0
...
0
...
0
Telegram
word
0
13
14
15
0
...
0
209