Communication according to PROFIdrive
3.4 Acyclic communication
The following options are available for reading and writing parameters:
● S7 protocol
This protocol uses the Startdrive commissioning tool in online operation via
PROFIBUS/PROFINET.
● PROFIdrive parameter channel with the following data sets:
– PROFIBUS: Data block 47 (0x002F)
– PROFINET: Data block 47 and 0xB02F al global access, data set 0xB02E as local
52
The DPV1 services are available for master class 1 and class 2.
access
Note
A detailed description of acyclic communication is provided in the following reference:
• References: PROFIdrive profile
You can obtain the current version from "PROFIBUS and PROFINET International
(PI) (https://www.profibus.com/download/profidrive-profile-drive-technology/)".
Addressing:
• PROFIBUS DP
The addressing is carried out via the logical address or the diagnostics address.
• PROFINET IO
The addressing is only undertaken using a diagnostics address which is assigned
to a module as of slot 1. Parameters cannot be accessed via socket 0.