Setting item
The following items are provided in the refresh settings.
Item
Refresh at the set timing
Refresh Timing
*1
Refresh Timing (I/O)
Inter-module synchronous
interrupt function
Refresh Timing (Synchronous Interrupt)
*1 For the high-speed counter module, the default setting cannot be changed.
■Refresh Timing
Set the refresh timing of the specified refresh destination.
Setting value
At the Execution Time of END Instruction
At the Execution Time of Specified Program
At the Execution Time of Synchronous Interrupt Program between Unit
2 PARAMETER SETTINGS
44
2.5 Refresh Setting
Transfer to the CPU
Transfer to the CPU
*1
Present value
Sampling/cycle counter flag
Counter function update flag
Latch count value
Sampling count value
Cycle pulse count previous value
Cycle pulse count current value
Cycle pulse count difference value (L)
Cycle pulse count difference value (H)
Overflow detection
Pulse under-measurement flag
Measured pulse value update flag
Measured pulse value
Signal monitor
Refresh Group
Refresh Group [n] (n: 1-64)
Refresh Timing
Synchronization latch count value
Synchronization measured pulse value
Refresh Group
Description
The refresh is performed when the END instruction of the CPU module is
executed.
The refresh is performed when the program specified in "Group [n]" is executed.
The refresh is performed when the interrupt program by the interrupt pointer is
executed.
Reference
Page 62 CH1 Present value
Page 64 CH1 Sampling/cycle counter flag
Page 66 CH1 Counter function update flag
Page 64 CH1 Latch count value
Page 64 CH1 Sampling count value
Page 64 CH1 Cycle pulse count previous
value
Page 65 CH1 Cycle pulse count current
value
Page 65 CH1 Cycle pulse count difference
value
Page 63 CH1 Overflow detection
Page 68 CH1 Pulse under-measurement
flag
Page 68 CH1 Measured pulse value
update flag
Page 68 CH1 Measured pulse value
Page 66 CH1 Signal monitor
Page 44 Refresh Timing
Page 44 Refresh Timing